XII EUROPEAN CONFERENCE - JUNE 2007

TECHNOLOGICAL INNOVATIONS IN AIR CONDITIONING
AND REFRIGERATION INDUSTRY
UNDER THE AUSPICES OF THE ENVIRONMENT MINISTRY

ARE AVAILABLE THE CONFERENCE PROOCEDINGS
OF THE XII EUROPEAN CONFERENCE
CLICK HERE

PROOCEDINGS

FIRST SESSION

NEW REFRIGERANTS AND PERSPECTIVES: NEW EUROPEAN REGULATIONS ON F-GASES

Future opportunities for refrigeration sector in safeguarding climate system - R. Shende - United Nations Environment Programme
Shende eng.pdf

The environmental challenge - D. Coulomb - International Institute of Refrigeration
Coulomb_eng.pdf

Perspectives on refrigerants with regulations on energy use - L. Lucas - Association Française du Froid
Lucas_eng.pdf

Initiatives in North America to use refrigerants responsibly - M. Menzer - Air Conditioning and Refrigeration Institute Menzer_eng.pdf

Initiatives of Ashrae to use natural refrigerants - T. Phoenix - ASHRAE
Phoenix_eng ultimiss.pdf

New or old refrigerants what is best choice? - H. Halozan - Graz University of Technology
Halozan_eng.pdf

How to lower environmental impacts? Latest technologies to reduce refrigerant charge, to recovery and to check for leaks - D. Clodic - Center for Energy and Processes - CEP
Clodic.pdf

New technologies and application of carbon dioxide as refrigerant - P. Neksa - Sintef Energy Research
Neksa_eng.pdf

Designing and operating safe ammonia refrigeration systems comparison with CO2 - A. Pearson - Star Refrigeration Ltd Pearson.pdf

New refrigerant fluids to meet demanding environmental criteria - B. Minor, E. Youngdale - Du Pont Fluorochemicals Dupont.pdf

Substitution of HCFC in refrigeration and air conditioning plants - E. Campagna - Rivoira; N. Roberts - Du Pont Fluorochemicals
campagna_eng.pdf

Trends for refrigerants in compression systems - J. Suss - Danfoss
suess_eng.pdf

Working towards more environmentally friendly refrigerant blends - N. Cox - Earthcare Products Ltd
Coxgiusto_eng.pdf

New technologies in lubrificants - C. Zilio - University of Padova
zilio-inglese.pdf

 

SECOND SESSION

NEW COMPONENTS AND EQUIPMENT  IN RELATION TO NEW ENERGY
AND ENVIRONMENTAL ISSUES AND NEW REFRIGERANTS

Equipment and systems - L. Lucas - Association Française du Froid
Lucas_eng.pdf

Introduction to magnetic refrigeration - P. W. Egolf - University of Applied Sciences of Western Switzerland
Egolf 1_eng.pdf

PThe environment, the energy saving and the safety os f secondary refrigerants - M. Barth - Institut Français du Froid Industriel
barth-eng.pdf

Solar cooling technologies - F. Asdrubali - University of Perugia
Asdrubali_inglese.pdf

New technologies in heat exchanger - H. Quack - Technische Universitat Dresden
Quack_eng.pdf

New technologies in CO2 gas cooler - G. Lozza - Politecnico of Milano
lozza.pdf

Carbon dioxide in refrigeration plants and in heat pumps - G. Pisano - Officine Mario Dorin
Dorin ultimissima.pdf

New technologies in scroll compressors - W. Bianchi, E. Winandy - Copeland Europe
Copeland_eng.pdf

New technologies  of energy saving in screw compressors - E. Fornasieri, M.Corradi, L. Cecchinato - University of Padova; P. Trevisan - Bitzer
bitzer_eng.pdf

New technologies in hydrocarbon heat pump - P. Valero, M. Zgliczynski - Embraco
Embraco - Milano 2007_eng.pdf

New control system in air conditioning for telecommunication - T. Ferrarese - Carel
Carel_eng.pdf

New energy efficiency control in chillers - L. Cecchinato - University of Padova
Cecchinato Rhoss_eng.pdf

New technologies in the coabsorbent cycle - M. N. Staicovici - Absorption Engineering
Staicovici_eng.pdf

 

THIRD SESSION

OPEN DISCUSSION ON ENERGY AND ENVIRONMENTAL ISSUES,
NEW FLUIDS, NEW COMPONENTS AND NEW PLANTS IN REFRIGERATION AND AIR CONDITIONING:
NEW EUROPEAN REGULATION
  ON F-GASES

D. Coulomb - International Institute of refrigeration Didier Coulomb.pdf

M. Avraamides - European Commission Avraamides_3rd session.pdf

M. Menzer - ARI Menzer_3rd_session.pdf

M. Masoero - Politecnico of Torino Masoero_3rd session.pdf

R. camporese - CNR ITC of Padova camporese_3rd session.pdf

M. Collantin - consultant collantin_3rd_session.pdf

 

FOURTH SESSION

EUROPEAN AND INTERNATIONAL LAWS, CERTIFICATION AND LICENCES
IN REFRIGERATION AND AIR CONDITIONING

Regulating fluorinated refrigerants: the EU regulation - M. Avraamides - European Commission
Milan Conference 2007-MAvraamides.pdf

European refrigeration training and certification - J. Hoogkamer - Air conditioning and Refrigeration European Association AREA ULTIMO.pdf

Latest european regulations on refrigerants and energy efficiency - F. Bush - European Partnership for Energy and the Environment
Busch_eng.pdf

Certifications and energy auditing of air conditioning systems - M. Masoero - Politecnico of Torino
Masoero_eng.pdf

Tests and normatives for heat recovery on exhausted air - M. Serraino - Politecnico of Torino; G. Ranzato - Clivet
paper ranzato serraino.pdf

Performance inspection of HVAC/R systems to save energy - K. Berglof - Climacheck
Berglof - Climachek_eng.pdf

A few words of conclusion on refrigeration technician training - A. Sacchi - Politecnico of Torino
SACCHI presentazione ATF english2.pdf

 

FIFTH SESSION

NEW CONTROL TECHNOLOGIES THE COLD CHAIN
Cold storage and transport

Energy recovery in the cold chain - G. Panno - University of Palermo
Panno paper rigassificatori.pdf

CO2 in the cold chain: transcritical R744 bottle cooler - L. Cecchinato, E. Fornasieri - University of Padova; C. Fossati - Mondial Group
Cecchinato Mondial_eng.pdf

New technology in the cold chain using natural refrigerants - P. Amirante - University of stidies of Bari
Amirante_engl.pdf

New technologies in CO2 compressor for light commercial refrigeration - M. Bassi - Embraco
Embraco Maciel.pdf

Transcritical CO2 systems in the cold chain - S. Da Ros - EPTA Group
EPTA Group.pdf

Solar chill cooler and refrigerator for the cold chain - J. Maté - Solarchill Project Coordinator (Greenpeace International) mate_eng.pdf

Controls in the cold chain
Leak detection and plant maintenance - D. Branchi - Testo
testo-eng.pdf

New solutions in the cold chain: secondary fluid systems - A. Pianetti - George Fischer
Georg Fisher_eng.pdf

Eco-design of commercial refrigerators and freezers - S. Iyama - Bio Intelligence Service
Bio_EuP_ENG.pdf

 

XI EUROPEAN CONFERENCE POLITECNICO OF MILAN - JUNE 2005

ON  TECHNOLOGICAL  INNOVATIONS
IN  AIR  CONDITIONING   AND  REFRIGERATION
UNDER THE AUSPICES OF THE ENVIRONMENT MINISTRY

PROOCEDINGS

FIRST SESSION

NEW REFRIGERANTS AND PERSPECTIVES: NEW EUROPEAN REGULATIONS

IIR listing refrigeration research priorities - D. Coulomb - International Institute of Refrigeration Coulomb IIR Ingl.pdf

Consequences of the current evolution in regulations - L. Lucas - Associations Francaise du Froid Lucas AFF Ingl.pdf

Remarks on emission of fluorocarbons CFCS, HCFCS and HFCS - F. Billiard - Direttore Onorario dell'Istituto Internazionale del Freddo Billiard Ing._.pdf

Refrigerant Issues -Refrigerant emissions, how important are they? - P. Neksa - Sintef Energy Research Neksa SINTEF Ingl.pdf

Advances in supermarket refrigeration leak reduction - C. Meurer,A. Nicoletti - Solvay Fluor Meurer-Nicoletti SOLVAY ingl.pdf

R407C: practical consequences of composition shift - J. Morley - Dupont Fluoroproducts Morley DUPONT Ing.pdf

R-22 replacements in air conditioning applications - R-407C and R-410A: what does the future hold? - E. Campagna - Rivoira SPA Campagna RIVOIRA Ing.pdf

Evaluation of alternative refrigerants when retrofitting -22 refrigeration systems - C. Soffientini - Honeywell Soffientini HONEYWELL Ing.pdf

Energy saving refrigerant blends comprising R125, R134a, R600 or R600a - N. A. Roberts - Rhodia UK LTD Roberts RHODIA Ingl.pdf

New technology for secondary heat transfer fluids - T. Lansbergen - ARTECO Lansbergen ARTECO Ing.pdf

Lubrificants for synthetic and natural refrigerants:effects on system efficiency - C. Zilio - Università di Padova Zilio English.pdf

 

SECOND SESSION

NEW COMPONENTS AND EQUIPMENT CONCERNING NEW REFRIGERANTS
IN RELATION TO ENERGY EFFICIENCY OF INSTALLATIONS

New components and equipment in relation with energy and refrigeranst - L. Lucas - Associations Francaise du Froid Lucas AFF ingl.pdf

A simple efficient prototype of a magnetic refrigerator - P. W. Egolf - University of Applied Sciences of Western Switzerland Egolf UNIV SVIZZ.pdf

Presentation of new technologies - Ice slurry generators - M. Barth - Institut Francais du Froid Industriel barth inglese.pdf

Highly efficient air conditioning systems - H. Halozan - Graz University Halozan GRAZ UNIVERSITY Ingl.pdf

Perspectives of solar assisted heat pumps with bare solar panel evaporators - L. Tagliafico - Università di Genova tagliafico_eng_tgl.pdf

Sub-critical operation of the TU Dresden CO2 expander/compressor - H. Quack - Technische Universitaet Dresden Quack-Riha UNIV DRESDA ing.pdf

CO2 - A future refrigerant? - J. Suss - Danfoss Suss DANFOSS Ingl.pdf

Performance improvements in commercial refrigeration with vapour injected scroll compressors - W. Bianchi, E. Winandy - Copeland Europe Bianchi COPELAND Ing.pdf

A new generation of compact screw compressors optimised for R134a - H. Renz - Bitzer Renz BITZER Ing.pdf

Some methods of oil level control in the cranckcase of compressors connected in parallel - L. Cecchinato, M. Barbieri - Università di Padova, TEKLAB Cecchinato UN PADOVA -TEKLAB Ing.pdf

 

THIRD SESSION

OPEN DISCUSSION ON OPEN DISCUSSION ON ENERGY ISSUES,
NEW FLUIDS AND REFRIGERATION TECHNICIAN TRAINING
WITH REFERENCE TO EUROPEAN REGULATION
  ON F-GASES

Potential in refrigeration and air conditioning industry - R. Shende - United Nations Environment Programme Shende UNEP Ing.pdf

Energy issues: an insight - F. Billiard - Direttore Onorario dell'Istituto Internazionale del Freddo Billiard IIR Ing.pdf

The EU regulation - Emission levels, energy efficiency and rechnical qualifications - T. Vink - Honeywell Vink HONEYWELL Ing.pdf

The european partnership for energy and the environment's (EPEE) role in the EU decision making process - F. Busch - EPEE Busch EPEE Ing.pdf

 

FORTH SESSION

EUROPEAN LAWS, CERTIFICATION AND LICENCES
IN REFRIGERATION AND AIR CONDITIONING

The european RAC contractors - Training programmes, certifications and minimun requirements - J. Jacquin, R. Beerckmans - AREA Jacquin Berckmans AREA ing.pdf

Training of professionals energy saving compressor performance certification - A. Mearini - Association Francaise du Froid Mearini AFF Ingl.pdf

 

FIFTH SESSION

NEW CONTROL TECHNOLOGIES AND THE COLD CHAIN
Cold storage and transport

Refrigeration: technology for survival - R. Vallort - ASHRAE Vallort ASHRAE inglese.pdf

An experimental refrigerator with an inverse air cycle for freezing - IQF food products - A. Gigiel, G. Giuliani, F. Polonara, C. Vitale - Università Politecnica delle Marche Polonara UNIV MARCHE Ing.pdf

Optimisation installation, running and maintenance costs using a integrated control system and innovative technology - A. Greggio - CAREL SPA Greggio CAREL Ing.pdf

Managing of cooling circuits in the refrigerating chain - A. Canfailla - NCR BIOCHEMICAL Canfailla NCR Ing.pdf

Optimisation in cold chain: transports - G.Panozzo - I.T.C. CNR Padova Panozzo Ingl.pdf

CO2 AS REFRIGERANT
THEORICAL AND DESIGN ASPECTS

Properties of CO2 as refrigerant - A. Cavallini - Università di Padova Cavallini - Milano04CO2.pdf

Applications in mobile air-conditioning and applications in heat pumps - P. Neksa - Sintef Energy Research Neksa - 041127_CO2sem_Neksa_SINTEF.pdf

Life cycle climate performance of mobile air-conditioning systems with HCFC - 134a, HCFC - 152a and R-744 - P. Neksa - Sintef Energy Research Neksa - SINTEF_LCCP_MAC_CO2.pdf

Commercial and industrial refrigeration - S. Girotto Girotto testo_relazione_27-11_last_OK gb.doc

Design considerations when using Carbon Dioxide in industrial refrigeration systems - D. Blackhurst - Star Refrigeration LTD Blackhurst - 04-11-04 Milan Conference Paper.doc

Potential of Carbon Dioxide compressor technology for refrigeration appliances - R. Maciel - Embraco Maciel- CO2 Seminarin Milan - Embraco.ppt

Compressori frigoriferi per CO2 - G. Pisano - Officine Mario Dorin Pisano - Milano 11 2004 eng.doc

Semi-hermetic compressors for CO2 cascade systems - H. Renz - Bitzer Renz - CO2 Cascade Comp_Studi Galileo_1.ppt

Low-temperature delivery bodies - Micheletto, Rosso Micheletto Rosso - IMPIANTI TRANSCRITICI.doc

Integration of a three-stage exander into a CO2 refrigeration system - H. Quack - Technische Universitaet Dresden Quack - english.doc

X EUROPEAN CONFERENCE ON
TECHNOLOGICAL INNOVATIONS IN AIR CONDITIONING
AND REFRIGERATION INDUSTRY
WITH PARTICULAR REFERENCE TO NEW REFRIGERANTS,
NEW EUROPEAN REGULATIONS, NEW PLANTS - THE COLD CHAIN

 

FIRST SESSION

NEW REFRIGERANTS AND PERSPECTIVES: NEW EUROPEAN REGULATIONS

New Trends in Refrigerating Equipment and Refrigerants Franois Billiard Director of the International Institute of Refrigeration

CO2 refrigeration, air conditioning and heat pump technology - Petter Neksa - Geir Skaugen   Sintef Energy Researche' - Jostein Pettersen   Norwegian University

Refrigerant conservation programs in international perspective - Jos Bouma    IEA   Heat Pump Centre

Natural refrigerants for industrial refrigeration - Andy Pearson   Star Refrigeration

The Future of HFCs as Refrigeration Working Fluids - John Morley   DuPont Fluoroproducts

The Use of R-407C: Applications and Guidelines - Ennio Campagna   Rivoira    John Morley   DuPont

HFC-245fa: an overview of properties and applications - Cesare Soffientini   Honeywell

The development of a low temperature blend of R125, R134a with either R600 or  R600a - Neil A. Roberts    Rhodia Organique Fine

Development of lubrificants for industrial refrigeration - Piermario Banfi  - A.P. Swallow    Castrol

A Critical Assessment of Synthetic Lubricant Technologies for Alternative  Refrigerants - Dr S. J. Randles    Uniqema

An assessment of capped polyalkylene glycol technology for CO2 refrigeration - Elizabeth Dixon    Laporte

SECOND SESSION

NEW COMPONENTS AND EQUIPMENT CONCERNING NEW REFRIGERANTS
IN RELATION TO ENERGY EFFICIENCY OF INSTALLATIONS

Multifunctional Thermal Fluids for Refrigeration and Air Conditioning - Peter W. Egolf   Ice Slurry Working Party   International Institute of Refrigeration

Presentation of new technologies ice slurry generators - Michel Barth   Association Franaise du Froid    Compagnie des experts du froid et de la cimatisation  Institut   Franais du Froid Indusriel

The miniaturization of the lithium bromide direct-fired absorption chillers/heaters - Fabio Braidotti    Systema

High efficiency commercial compressor noise reduction experience - Jan Kakalejcik - Marek Zgliczynski    Embraco

Europe HFCs regulation

Two Innovative Technologies for Air Conditioning Plants - Ignazio Renato Bellobono - Vincenzo Picone - Claudio Lagrasta - Sergio Fusi   University of Milano

FIFTH SESSION

NEW CONTROL TECHNOLOGIES AND THE COLD CHAIN
COLD STORAGE AND TRANSPORT

Security in keeping on the "cold-chain": how to grant that the professional refrigerating appliances requirements are like to those stated in the original project; correlation between the labs data and the one obtained by the testing checks made while the cabinet is still on the assembling lineClaudio Fossati   Mondial Elite

Critical points during the loading of frozen goods: how to obtain a dramatic energy saving together with the certainty of the non perishing of the food - G. Paolo Nelzi   Campisa

VIP . Formulas and Rules for designers and final users -  Pierattilio Di Gregorio   Saes Advanced Technologies